top of page

DUAL IMPLANT

Made by expert

Titan Industries Egypt is a company dedicated to designing and manufacturing the DUAL Dental Implant system. We aim to offer dental clinicians complete and reliable evidence-based dental implant solutions. The system has been designed by experts in the field of dental implantology and mechanics who took into consideration the ideal biomechanical features providing a reliable product with guaranteed quality.

WhatsApp Image 2024-11-29 at 11.12_edited.png

Our Story

2020 is a milestone in our company’s life opening a branch distribution Centre in Cairo - Egypt, nowadays we have been providing service for our customers in more than 27 governorates in Egypt, hence having excellent conditions for expanding mainly in Africa.

 

Holding high esteem, practical knowledge and education, we have opened our DUAL Implant Academy, where medical educational training, advanced implantology courses can be provided for oral surgeons visiting us from different parts of the world.

​

​DUAL Implant system provides excellent products with competitive prices and strong support. We use the most precise tools and equipment with the best material available meeting the international quality standard ISO 13485:2016. All our implants are made of biocompatible grade 23 titanium alloy with an outstanding surface micro-topography inspected with very precise quality control.

​

alo abutment000100.14.png

Certifications

Egyptian_drug_authority.png

 DUAL implant (dental implant system) is registered with the Egyptian Drug Authority and supervised by EDA inspection   department

 

EDA Reg No : R102287Lrn23V1

EDA Operation license code for factory : LiMD2022005/0042022

EDA Certificate of GMP compliance : M-1722/2024

ISO 13485/2016 : Certificate No 211129032001

​

     DUAL implant undergoes strict manufacturing process. The packaging process performed in our specially designed iso class D clean rooms. Then sterilized by gamma radiation in the Egyptian Atomic Energy Authority.

Egyptian-Atomic-Energy-Authority-e1587597058309.png
Untitled-1_edited.png

IMPLANTS FEATURES

  1.  Material: grade 23 titanium (Higher purity version of titanium grade 5).

  2. Smart tapered design: provide compressive loading and excellent primary stability.

  3. Triple lead threads: ( faster insertion – increase thread engagement).

  4.  Hybrid Thread design: ( standard V-shaped thread at apical part higher 1ry stability – self- drilling and self cutting. Square thread design at coronal part: greater Bone-Implant Contact (BIC) and higher reverse torque.

  5. Progressive threads: increase the load transfer to the more flexible cancellous bone instead of crestal cortical bone. This may contribute to less cortical bone resorption. 0.2mm (Shallow thread depth) at coronal part: permits easier insertion into denser bone with no need for tapping. 0.6 mm at apical part: advantage in areas of soft bone and higher occlusal loads.

  6. Universal connection: for all implant diameters which makes the prosthetic step much easier and color-coded for quick identification and component matching and with restorative ease 45° conical internal hex connection. we have a mini-implant line with smaller connection dimensions.

  7. Platform switching: provides excellent bone maintenance and soft tissue volume, ideal for esthetically demanding cases.

  8. Safe Rounded apex: Patients indicated for minimally invasive crestal maxillary sinus floor elevation approach, the safe  round fixture apex pushes Sinus membrane without causing harm.

3.png
Implant_edited.png

The New innovative High-energy surface

 

DUAL implant introduces hydrophilic surface implants that can achieve accelerated bone healing by promoting rapid protein adsorption and accelerated union between the implant and the bone.

 

In recent years, as a result of the application of different physical and biochemical treatments in DUAL biochemical Labs, a new generation of so-called High-Energy Surface implants have emerged; these surfaces are capable of accelerating cellular differentiation in the osteogenic pathway, improving upon the results of the standard SLA surface implants. The improvement in the properties of the implant surfaces is even more relevant in cases of poor bone quality or in treatments in which shortened loading times are the intended outcome.

 

Single and two-Piece implants are available with the standard SLA surface only or with the added new H.E.S surface technology.

H.E.S Surface-.png
assembly all 0.23.png

Surface treatment

 DUAL implant is subjected to a heavy subtractive  acid-etching protocol that creates an intense micro-textured surface with interconnecting capillaries and micropores forming the S.L.A surface that allows for quick osteoblastic adhesion to the implant surface.

 
4.1.png

Contact Us

Tel. (02) 25735981

Sales. 01064993366

Customer service. 01065556657

  • Black Facebook Icon
  • Whatsapp
  • Whatsapp
  • Black Instagram Icon

Thanks for submitting!

bottom of page